{"product_id":"cbb60-25uf-250v-motor-start-run-capacitor","title":"CBB60 25MFD 25uF 250V AC Capacitor 2-Wire for Washing Machine Pump Motor","description":"\u003c!-- 产品描述开始 --\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eCBB60 25µF 250VAC Motor Start-Run Capacitor – for Washer Pumps\u003c\/h1\u003e\n\n\u003cp\u003eThis \u003cstrong\u003eCBB60 25µF (25MFD) 250VAC capacitor\u003c\/strong\u003e uses metallized polypropylene film in a flame-retardant case with \u003cstrong\u003e2-wire leads\u003c\/strong\u003e, built for start-run duty in single-phase AC motors. A direct replacement for \u003cstrong\u003ewashing machine drain pump motors\u003c\/strong\u003e and small appliance motors specifying 25µF. Sitting between our 20µF and 30µF listings, this value covers machines with slightly higher starting requirements than the baseline 20µF spec without jumping to the full 30µF.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eType:\u003c\/strong\u003e CBB60 metallized polypropylene film capacitor\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eCapacitance:\u003c\/strong\u003e 25µF (25MFD)\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 250V AC\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eDuty:\u003c\/strong\u003e Motor start-run (continuous run with start assist)\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eLeads:\u003c\/strong\u003e 2-wire outlet (tinned copper, non-polarized)\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eSelf-healing dielectric\u003c\/strong\u003e – recovers from micro-breakdown\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eLow dissipation factor\u003c\/strong\u003e – runs cool under load\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eFlame-retardant molded case\u003c\/strong\u003e (UL94-V0 class typical)\u003c\/li\u003e\n\t\u003cli\u003e✅ RoHS compliant, no PCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%; max-width:640px;\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth align=\"left\"\u003eParameter\u003c\/th\u003e\n\t\t\t\u003cth align=\"left\"\u003eValue\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCapacitor Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCBB60 (Metallized Polypropylene Film)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCapacitance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e25µF \/ 25MFD\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e250V AC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eTolerance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e±5% (J) typical\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eDuty Class\u003c\/td\u003e\n\t\t\t\u003ctd\u003eMotor start-run (per IEC 60252-1 Class B\/C)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eNumber of Leads\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2 wires (non-polarized)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eDielectric\u003c\/td\u003e\n\t\t\t\u003ctd\u003eMetallized polypropylene film\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e-40°C to +70°C (some to +85°C)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCase Material\u003c\/td\u003e\n\t\t\t\u003ctd\u003eFlame-retardant molded plastic\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMounting\u003c\/td\u003e\n\t\t\t\u003ctd\u003eScrew tab \/ cable tie bracket (model dependent)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCompliance\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRoHS, IEC 60252-1 reference\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eWashing machine \u003cstrong\u003edrain pump motors\u003c\/strong\u003e (25µF spec)\u003c\/li\u003e\n\t\u003cli\u003eWasher spin \/ circulation pump motors\u003c\/li\u003e\n\t\u003cli\u003eDishwasher drain pump motors\u003c\/li\u003e\n\t\u003cli\u003eSmall water pump \u0026amp; fountain pump motors (250V class)\u003c\/li\u003e\n\t\u003cli\u003eSingle-phase AC induction motors requiring 25µF start-run assist\u003c\/li\u003e\n\t\u003cli\u003eCompactor \/ small appliance motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e20 \/ 25 \/ 30µF – Which Do You Need?\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e20µF:\u003c\/strong\u003e Most common – standard front-load washer drain pumps.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e25µF:\u003c\/strong\u003e Mid-point – some machines specify exactly 25µF (often European or Asian models with specific pump motors). If your old cap reads 25µF, this is the correct part.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e30µF:\u003c\/strong\u003e Larger pumps, some top-load and commercial units.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eRule:\u003c\/strong\u003e Always read the old capacitor's printed label. Using the wrong µF changes motor torque characteristics and can cause overheating or failure to start.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Replacement\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eNon-polarized:\u003c\/strong\u003e Either wire goes to either motor terminal per the appliance schematic.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003ePower off + discharge:\u003c\/strong\u003e Unplug the washer, discharge old cap before touching leads.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eMatch values:\u003c\/strong\u003e Replace with 25µF ±5% and 250VAC or higher. Never substitute a lower voltage class.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eSymptom check:\u003c\/strong\u003e Pump hums but won't spin = classic failed run cap. Swap before condemning the motor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy This Cap\u003c\/h2\u003e\n\n\u003cp\u003eSome washers – particularly certain European and Asian models – specify exactly \u003cstrong\u003e25µF\u003c\/strong\u003e for their drain pump motors. This isn't a \"close enough\" 20 or 30 situation; the manufacturer tuned the motor for that specific value. This \u003cstrong\u003eCBB60 25µF 250VAC\u003c\/strong\u003e delivers the correct starting torque with low-loss PP film that stays cool through repeated cycles. Self-healing dielectric handles occasional overstress, and the 2-wire lead-out drops straight into existing connectors. If your old cap reads 25µF, this is the right part – no guessing, no compromise.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOrder today\u003c\/strong\u003e – fast worldwide shipping on CBB60 washer pump capacitors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 产品描述结束 --\u003e","brand":"DIYMars","offers":[{"title":"Default Title","offer_id":53367945625911,"sku":"B60W250V25U","price":7.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0894\/5562\/4503\/files\/57_2e30b9b4-0fa5-4bff-b3ad-2b0fee62e511.png?v=1792384068","url":"https:\/\/www.diymars.com\/products\/cbb60-25uf-250v-motor-start-run-capacitor","provider":"DIYMars","version":"1.0","type":"link"}