{"product_id":"cbb60-30mfd-250v-motor-start-run-capacitor","title":"CBB60 30MFD 30uF 250V AC Capacitor 2-Wire for Washing Machine Pump Motor","description":"\u003c!-- 产品描述开始 --\u003e\n\u003cdiv class=\"product-description\"\u003e\n\u003ch1\u003eCBB60 30µF 250VAC Motor Start-Run Capacitor – for Washer Pumps\u003c\/h1\u003e\n\n\u003cp\u003eThis \u003cstrong\u003eCBB60 30µF (30MFD) 250VAC capacitor\u003c\/strong\u003e uses metallized polypropylene film in a flame-retardant case with \u003cstrong\u003e2-wire leads\u003c\/strong\u003e, built for start-run duty in single-phase AC motors. A direct replacement for \u003cstrong\u003ewashing machine drain pump motors\u003c\/strong\u003e, larger small-appliance motors, and light commercial pump units where 30µF is the specified value.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eType:\u003c\/strong\u003e CBB60 metallized polypropylene film capacitor\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eCapacitance:\u003c\/strong\u003e 30µF (30MFD)\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 250V AC\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eDuty:\u003c\/strong\u003e Motor start-run (continuous run with start assist)\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eLeads:\u003c\/strong\u003e 2-wire outlet (tinned copper, non-polarized)\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eSelf-healing dielectric\u003c\/strong\u003e – recovers from micro-breakdown\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eLow dissipation factor\u003c\/strong\u003e – runs cool under load\u003c\/li\u003e\n\t\u003cli\u003e✅ \u003cstrong\u003eFlame-retardant molded case\u003c\/strong\u003e (UL94-V0 class typical)\u003c\/li\u003e\n\t\u003cli\u003e✅ RoHS compliant, no PCB\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\n\u003ctable border=\"1\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse; width:100%; max-width:640px;\"\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth align=\"left\"\u003eParameter\u003c\/th\u003e\n\t\t\t\u003cth align=\"left\"\u003eValue\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCapacitor Type\u003c\/td\u003e\n\t\t\t\u003ctd\u003eCBB60 (Metallized Polypropylene Film)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCapacitance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e30µF \/ 30MFD\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\t\t\t\u003ctd\u003e250V AC\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eTolerance\u003c\/td\u003e\n\t\t\t\u003ctd\u003e±5% (J) typical\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eDuty Class\u003c\/td\u003e\n\t\t\t\u003ctd\u003eMotor start-run (per IEC 60252-1 Class B\/C)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eNumber of Leads\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2 wires (non-polarized)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eDielectric\u003c\/td\u003e\n\t\t\t\u003ctd\u003eMetallized polypropylene film\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\t\t\t\u003ctd\u003e-40°C to +70°C (some to +85°C)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCase Material\u003c\/td\u003e\n\t\t\t\u003ctd\u003eFlame-retardant molded plastic\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMounting\u003c\/td\u003e\n\t\t\t\u003ctd\u003eScrew tab \/ cable tie bracket (model dependent)\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCompliance\u003c\/td\u003e\n\t\t\t\u003ctd\u003eRoHS, IEC 60252-1 reference\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eWashing machine \u003cstrong\u003edrain pump motors\u003c\/strong\u003e (30µF spec)\u003c\/li\u003e\n\t\u003cli\u003eWasher spin \/ circulation pump motors\u003c\/li\u003e\n\t\u003cli\u003eDishwasher drain pump motors\u003c\/li\u003e\n\t\u003cli\u003eSmall water pump \u0026amp; fountain pump motors (250V class)\u003c\/li\u003e\n\t\u003cli\u003eSingle-phase AC induction motors requiring 30µF start-run assist\u003c\/li\u003e\n\t\u003cli\u003eCompactor \/ small appliance motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003e20µF vs 30µF – Which Do You Need?\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e20µF:\u003c\/strong\u003e Common on smaller drain pumps (most front-load washers).\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003e30µF:\u003c\/strong\u003e Used on larger pumps or machines with higher starting torque requirements (some top-load, commercial, or pump+spin combo units).\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eDon't guess:\u003c\/strong\u003e Read the old capacitor's label. Using the wrong µF changes motor torque and can cause overheating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Replacement\u003c\/h2\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eNon-polarized:\u003c\/strong\u003e Either wire goes to either motor terminal per the appliance schematic.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003ePower off + discharge:\u003c\/strong\u003e Unplug the washer, discharge old cap before touching leads.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eMatch values:\u003c\/strong\u003e Replace with 30µF ±5% and 250VAC or higher. Never drop to a lower voltage class.\u003c\/li\u003e\n\t\u003cli\u003e\n\u003cstrong\u003eSymptom check:\u003c\/strong\u003e Pump hums but won't spin = classic failed run cap. Swap before condemning the motor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWhy This Cap\u003c\/h2\u003e\n\n\u003cp\u003eA washer pump that buzzes but won't turn is almost always a dead capacitor, not a burned-out motor. This \u003cstrong\u003eCBB60 30µF 250VAC\u003c\/strong\u003e restores starting torque with low-loss PP film that stays cool through repeated high-torque starts. Self-healing dielectric means occasional overstress won't immediately kill it, and the 2-wire lead-out drops straight into existing connectors. If your machine calls for 30µF, this is the right part.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOrder today\u003c\/strong\u003e – fast worldwide shipping on CBB60 washer pump capacitors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- 产品描述结束 --\u003e","brand":"DIYMars","offers":[{"title":"Default Title","offer_id":53367842406711,"sku":"B60W250V30U","price":7.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0894\/5562\/4503\/files\/57_695bbf31-182a-43bc-b83c-61de4657a25d.jpg?v=1792381067","url":"https:\/\/www.diymars.com\/products\/cbb60-30mfd-250v-motor-start-run-capacitor","provider":"DIYMars","version":"1.0","type":"link"}